Health ArticleEducational review — not personal medical advice

Which MRI Scan Shows Knee Growth Plate Closure More Reliably?

Specialized cartilage sequences were consistently more reliable than standard T1W sequences for assessing knee growth plate closure. Researchers in Sweden examined 395 healthy adolescents and young adults with MRI and provide age-by-age reference data for the distal femur and proximal tibia.

23 min

Table of Contents

Key Points

  • In a study of 395 healthy volunteers aged 14 to 21.5, cartilage MRI sequences were more reliable than T1-weighted sequences for grading knee growth plate closure.
  • Pediatric radiologists agreed with each other 82 to 90 percent on T1-weighted images and 93 to 95 percent on cartilage sequences; general radiologists agreed only 56 to 69 percent.
  • A residual physis can appear as incomplete closure on T1-weighted images even when the growth plate is fully fused, potentially causing under-grading.
  • Growth plate closure timing varies widely; complete thigh bone closure appeared as early as age 15 in females, yet some females still showed nearly complete closure at 21.

Background: Why Growth Plates Matter

The growth plate (also called the physis) is a layer of cartilage located near the ends of long bones in children and adolescents. It is where new bone forms as a child grows taller. Understanding when and how growth plates close is essential for several reasons.

Growth plate problems can cause short stature if something disrupts normal development. Conditions that may affect the growth plate include fractures (such as Salter–Harris injuries), bone infections (osteomyelitis), bone death from loss of blood supply (osteonecrosis), and bone dysplasias (disorders of bone development).

Doctors also need to assess growth plate closure for medicolegal reasons, such as determining the age of young athletes, and more recently, estimating the age of refugees who lack official documentation of their birth date. Forensic medicine has shown increasing interest in growth plate assessment for age estimation, making reliable imaging techniques critically important.

Traditionally, bone development has been evaluated with plain radiographs (X-rays) of the hand and wrist, using reference atlases such as the Greulich–Pyle (GP) and Tanner–Whitehouse (TW) methods. A less well-known method uses knee radiographs, based on the Pyle and Hoerr atlas. X-rays have two important limitations: they expose patients to ionizing radiation, and they show bone rather than the cartilage of the growth plate directly.

MRI (magnetic resonance imaging) offers a radiation-free alternative. It works by exploiting the water content of cartilage, which is about 70% water by volume. On standard T1-weighted (T1W) MRI sequences, cartilage appears as an intermediate (gray) signal, while on T2-weighted (T2W) sequences it appears bright (high signal). Specialized "cartilage sequences," including Gradient-Echo and water-selective techniques, have been developed to make cartilage appear even brighter and easier to evaluate.

Several different MRI sequences and rating scales have been used to grade growth plates in relation to age, but until now there has been no consensus on the most reliable approach. This study set out to answer two questions: (1) what is the normal state of growth plate closure at the knee in healthy adolescents and young adults, and (2) how reliable is grading when using cartilage sequences compared with T1W sequences, and does the reader's experience matter?

Study Methods: How the Research Was Conducted

Who Participated

This was a prospective, cross-sectional, multi-center study, meaning researchers enrolled participants going forward in time, collected data at one point in time, and used more than one study site. The study was approved by the ethics committee of Stockholm, Sweden, and followed the Declaration of Helsinki, an international set of ethical standards for medical research involving human participants.

Written informed consent was obtained from all adult participants, and consent/assent was collected from parents or legal guardians of participants under 18. Between October 2017 and April 2018, a total of 395 healthy volunteers were examined: 217 males and 178 females, ranging in age from 14.0 to 21.5 years.

Participants were randomly selected and had to meet strict criteria to be included: they had to be born in the country where the study was conducted (Sweden), and their age had to be verified by a birth certificate issued by national authorities. Volunteers were excluded if they had (1) a history of bilateral fractures or trauma to the knee, (2) a medical history of chronic disease or long-term medication use, (3) inability to comply with instructions during the MRI examination, (4) a history of living outside the country for more than six consecutive months, or (5) past or current pregnancy (all female subjects were tested).

Before imaging, researchers measured each participant's height and weight to calculate body mass index (BMI), and every participant completed a questionnaire about physical activity and inactivity levels.

The MRI Scanning

All MRI examinations were performed on a 1.5-T whole-body MR scanner (1.5-T refers to the magnetic field strength, measured in tesla) with dedicated knee coils. The knee on the non-dominant side was imaged, unless there was a history of fracture to that knee, in which case the dominant-side knee was scanned instead.

Three different MRI manufacturers' equipment was used at two sites:

  • Site 1 used Magnetom AvantoFit (Siemens Healthcare GmbH, Erlangen, Germany) and Achieva (Philips Healthcare, Amsterdam, The Netherlands)
  • Site 2 used Signa (GE Healthcare, Milwaukee, Wisconsin)

All MRI scans used a 160 × 160 mm field of view (the area being imaged) and a pixel resolution of 256 × 256. Each acquisition took approximately 4–5 minutes. Two types of sequences were obtained for each participant: a standard T1-weighted sequence and a specialized cartilage/water-sensitive sequence (a different sequence type depending on the scanner manufacturer).

The technical settings varied by machine but all used 3 mm slice thickness, with varying spacing between slices. The GE scanner used 1.5 mm spacing, while Philips and Siemens used 3 mm spacing between slices. Cartilage sequences used included MERGE (multiple echo recombined gradient echo) on GE, 3dWATSc (three-dimensional water selective cartilage scan) on Philips, and MEDIC (multi-echo data image combination) on Siemens.

How Images Were Graded

The researchers developed a staging system based on modifications of earlier systems by Dedouit et al., Kellinghaus et al., and Schmeling et al. The staging system grades the degree of closure, or fusion, of the growth plate based on the percentage of bone bridging — the process where bone replaces cartilage as growth finishes. The stages are:

  • Stage 1: Continuous, stripe-like cartilage signal is present between the metaphysis (the widening part of the bone shaft) and the epiphysis (the end of the bone), with a thickness greater than 1.5 mm and a multilaminar (multi-layered) appearance.
  • Stage 2: Continuous cartilage signal is present with thickness greater than 1.5 mm and increased signal intensity, but without the multilaminar appearance.
  • Stage 3: Continuous cartilage signal is present with a thickness of less than 1.5 mm and increased signal intensity.
  • Stage 4a: The cartilage is no longer continuous. A hazy area involving one-third or less of the growth plate is present, representing epiphyseal–metaphyseal fusion (the beginning of bone bridging between the bone end and shaft).
  • Stage 4b: The cartilage is not continuous. A hazy area involving between one-third and two-thirds of the growth plate is present, representing further fusion.
  • Stage 4c: The cartilage is not continuous. A hazy area involving more than two-thirds of the growth plate is present, representing nearly complete fusion.
  • Stage 5: The epiphyseal cartilage has fused completely, with or without an epiphyseal scar (a visible remnant of the former growth plate).

The slice with the highest grade of closure was selected and graded for each bone, except for stage 5, where all slices had to show complete closure. The same grading methodology was used regardless of sequence type, and grading was based on the percentage of bone bridging in the growth plate.

Two pediatric radiologists (with 3 and 13 years of experience) and two general radiologists (each with 2 years of experience in general MRI, including pediatric patients) independently graded the images. All were blinded to participant age and gender, as well as to each other's results. The femur (thigh bone) and tibia (shin bone) growth plates were graded separately on each sequence. When there was disagreement between observers, a third pediatric radiologist with 13 years of experience assessed the images to resolve the discrepancy.

After four weeks, the pediatric radiologist with 3 years of experience re-evaluated all images in both sequences to measure intra-observer agreement (how consistent one reader is with themselves over time).

Statistical Analysis

Researchers used two main statistical tools. The first was the intraclass correlation coefficient (ICC), with 95% confidence intervals — a measurement of how much agreement exists between ratings. An ICC above 0.9 was considered excellent agreement; 0.75–0.9 good; 0.5–0.75 moderate; and below 0.5 poor. A P-value below 0.05 (meaning less than a 5% chance the finding was due to random variation) was considered statistically significant.

The second tool was Cohen's kappa coefficient (κ), which measures agreement while accounting for agreement that would happen by chance alone. Kappa values were interpreted as: poor agreement below 0.20; fair agreement 0.20–0.40; moderate agreement 0.40–0.60; good agreement 0.60–0.80; and very good agreement 0.80–1.00.

Key Findings: Detailed Results

Demographics of the Study Population

A total of 395 volunteers completed the study. The age groups were well distributed, with between 36 and 61 participants in each yearly age bracket from 14 to 21 years. Among males, average height ranged from 171.0 cm at age 14 to 181.8 cm at age 21, and average weight ranged from 60.2 kg at age 14 to 76.5 kg at age 21. Among females, average height ranged from 163.2 cm at age 14 to 168.6 cm at age 21, and average weight ranged from 54.8 kg at age 18 to 66.7 kg at age 21.

When the Femur Growth Plate Closes

The femur (thigh bone) growth plate at the knee closes somewhat differently depending on which imaging sequence is used. On T1W sequences, the minimum age at which complete closure (stage 5) was observed was 16 years for males and 15 years for females. The maximum age at which stage 4b (one-third to two-thirds fused) was still seen was 19 years for males and 16 years for females. The minimum age for stage 4c (more than two-thirds fused) in males was 15 years. Notably, stage 4c was observed in every age group among females in this study.

On cartilage sequences, the minimum age for stage 5 in males was 16 years, while stage 5 was observed in every female age group. The maximum age for stage 4b was 18 years for males and 17 years for females. The maximum age for stage 4c was 19 years for males and 17 years for females.

When the Tibia Growth Plate Closes

For the tibia (shin bone), results were similar but with some differences. On T1W sequences, the minimum age for stage 5 was 16 years for males, while stage 5 was observed in every age group among females. The maximum age for stage 4b was 17 years for males and 15 years for females. The minimum age for stage 4c was 15 years for males, and stage 4c appeared in every female age group except 19- and 20-year-olds.

On cartilage sequences, the minimum age for stage 5 in males was slightly younger — 15 years — and stage 5 was again seen in every female age group. The maximum age for stage 4b was 17 years for males and 15 years for females. The maximum age for stage 4c was 19 years for males and 17 years for females.

Reliability: Cartilage Sequences Compared with T1W

The central finding of this study is that cartilage sequences produced substantially more reliable results than T1W sequences. This was true both when comparing different radiologists to each other (inter-observer agreement) and when testing whether the same radiologist got the same answer twice (intra-observer agreement).

For pediatric radiologists reading T1W sequences, inter-observer agreement was 82% (κ = 0.73, which is "good") for the femur and 90% (κ = 0.82, "very good") for the tibia. On cartilage sequences, agreement rose to 93% (κ = 0.86, "very good") for the femur and 95% (κ = 0.90, "very good") for the tibia.

For general radiologists reading T1W sequences, the results were notably lower: inter-observer agreement was 69% (κ = 0.56, "moderate") for the femur and only 56% (κ = 0.34, "fair") for the tibia. Because of the general radiologists' lower performance, the researchers decided to have only pediatric radiologists evaluate the cartilage sequences.

Intra-observer agreement (testing the same pediatric radiologist with 3 years of experience, reading images twice, four weeks apart) showed the same pattern:

  • Femur on T1W: 77% (κ = 0.65, "good")
  • Tibia on T1W: 87% (κ = 0.75, "good")
  • Femur on cartilage sequences: 89% (κ = 0.79, "good")
  • Tibia on cartilage sequences: 91% (κ = 0.81, "very good")

The intraclass correlation coefficients (ICC) were "excellent" overall, ranging from 0.90 to 0.97 across all comparisons. The highest inter-observer agreement was 95% for the tibia on cartilage sequences, and the highest intra-observer agreement was 91%, also for the tibia on cartilage sequences.

The "Residual Physis" Problem

An important observation emerged regarding a phenomenon the researchers call the "residual physis" — a remnant of the growth plate that appears not fully closed on T1W images even when closure is actually complete. A higher number of participants were graded as stage 4c rather than stage 5 on T1W compared with cartilage sequences. These cases showed a mostly ossified (bone-filled) growth plate that appeared minimally open at the edges on T1W.

This finding has been described by other researchers. Dvorak et al. called it a "residual physis," categorizing it as stage 5 in their six-stage system. Vieth et al. described it as a centrally thin-lined "fusion's scar" with a discontinuous line at the edges on T1W. Radiographic studies have also documented visible remnants of the growth plate (physeal scar) in both the knee and upper extremity. Faisant et al. found a physeal scar in at least one bone of the knee joint in 96% of females and 98% of males in a population aged 15 to 40 years.

In the current study, a residual physis was visible on T1W in the femur (both males and females) and in the tibia (males) across all older age groups, including 18–21-year-olds. One striking example: a 21-year-old female was graded as stage 4c on T1W (Table 4 in the original article). On re-assessment, the dorso-lateral (back and side) aspect of the growth plate appeared thick and blurry on T1W, consistent with a residual physis. However, on cartilage sequences, no residual cartilage was detectable, and no visible bright line remained — indicating the growth plate was completely fused, with only the epiphyseal bone plate remaining. This residual physis appearance could lead to individuals being under-graded as stage 4c instead of 5 when only T1W images are used.

Why Cartilage Sequences Are Easier to Read

The radiologists in this study reported that cartilage sequences were easier and less time-consuming to evaluate than T1W sequences. On cartilage sequences, the growth plate appears bright white against a dark background, and bone bridging appears as black columns invading the white cartilage. This high contrast makes it easier for the eye to detect even tiny bone bridges, especially in the early stages of closure.

On T1W sequences, by contrast, the growth plate cartilage appears grayish, making it difficult to distinguish nearly-white bone bridge tissue against a gray/black background. The researchers hypothesized that the water signal of the growth plate on a black background in cartilage sequences makes it easier to identify the discrete bone bridging that is hard to detect on T1W. Time was not formally measured in the study, so this feedback from observers is subjective, but it aligns with the objective reliability data.

Effect of Simplifying the Staging System

The researchers also tested whether simplifying their staging system — by removing the sub-classification of stage 4 (the 4a/4b/4c breakdown) — would improve agreement. Re-grading the images with this simpler system improved inter-observer agreement for pediatric radiologists on both T1W (femur: κ = 0.81; tibia: κ = 0.87) and cartilage sequences (femur: κ = 0.95; tibia: κ = 0.97). However, agreement for general radiologists remained unchanged (femur: κ = 0.56; tibia: κ = 0.34), reinforcing the conclusion that specialized pediatric radiology experience is valuable for this type of assessment.

Does Slice Spacing Matter?

An unexpected technical finding emerged when the researchers analyzed whether the spacing between image slices affected reliability. The GE scanner, which used 1.5 mm spacing between slices (with greater overlap), showed a lower kappa value — femur: κ = 0.85; tibia: κ = 0.88 — for the 297 individuals examined on that machine. In comparison, the Philips and Siemens scanners, which used 3 mm spacing between slices, showed higher kappa values — femur: κ = 0.91; tibia: κ = 0.96 — for the 98 individuals examined on those machines. This suggests that reducing slice overlap did not improve results and may have slightly reduced reliability, though the reasons for this are not fully clear.

Clinical Implications: What This Means for Patients

For patients, families, and clinicians, this study offers several practically important takeaways.

First, MRI is a radiation-free option. Unlike traditional X-rays of the hand and wrist, MRI does not expose young patients to ionizing radiation. For conditions where repeated imaging may be needed — such as monitoring a child with a growth-affecting condition — MRI is an attractive alternative that poses no radiation risk.

Second, the type of MRI sequence matters. Not all MRI scans are equally good at showing growth plate closure. This study demonstrates that cartilage sequences (water-sensitive sequences like 3dWATSc, MERGE, and MEDIC) are more reliable than standard T1W sequences for determining whether growth plates are open, partially closed, or fully fused. Patients whose doctors are specifically evaluating growth should ask whether a cartilage sequence is being included in the MRI protocol.

Third, experience matters. Pediatric radiologists — doctors with specialized training in imaging children — were substantially more accurate and consistent than general radiologists in assessing growth plate closure. On T1W sequences, pediatric radiologists achieved 82–90% agreement with each other, while general radiologists achieved only 56–69% agreement. The difference was most dramatic for the tibia, where general radiologists' agreement dropped to 56% (κ = 0.34, only "fair"). When growth plate assessment is important, referral to a center with pediatric radiology expertise is preferable.

Fourth, there are normal variations in growth plate closure timing. The data show that growth plate closure at the knee is a gradual process with wide individual variation, particularly among females. For example, while complete closure of the femur (stage 5) was seen as early as age 15 in females on T1W, some females still showed nearly complete but not total closure (stage 4c) at age 21. A "residual physis" appearance on T1W can misleadingly suggest incomplete closure when the growth plate is actually fused — a potential pitfall for age estimation that pediatric radiologists should be aware of.

Fifth, for age estimation purposes, chronological age is not the same as biological age. The researchers emphasize that even in the best of tests, chronological age (a person's calendar age) differs from biological age (the maturity of the skeleton). This distinction is important in medicolegal contexts, such as assessing the age of young refugees or athletes.

Limitations: What This Study Couldn't Prove

Every scientific study has limitations, and the authors are transparent about theirs. First, this study was designed to describe the state of growth plate closure clinically — it was intentionally not designed to estimate chronological age from MRI findings. Therefore, the authors state clearly that no conclusions about age estimation can be drawn from this data, and the study does not aspire to provide such estimates.

Second, the study population was limited to healthy individuals born in the country where the study was conducted (Sweden). The results may not apply to children and young adults from other countries or backgrounds, and the authors note that discrepancies between methods are more substantial when evaluating individuals from different strata than the original Greulich–Pyle and Tanner–Whitehouse cohorts.

Third, the study used a cross-sectional design, meaning each participant was imaged only once. The researchers could not track individual participants over time to see exactly when each person's growth plates closed, so the "minimum ages" and "maximum ages" reported are based on group data rather than longitudinal follow-up.

Fourth, the observation that cartilage sequences were easier and less time-consuming to evaluate was based on radiologists' subjective feedback, not formally measured data. Time to grade each image was not recorded as an objective outcome measure.

Fifth, the study used three different MRI machines from three manufacturers with slightly different sequence parameters. Although this reflects real-world clinical practice, it introduces variability that could affect the results. Notably, the scanner with smaller slice spacing (GE, 1.5 mm) produced lower kappa values than the scanners with 3 mm spacing, which was an unexpected finding that the researchers could not fully explain.

Finally, the tibia and femur were each graded on a single selected slice (except for stage 5, which required all slices to be closed). This simplified approach may not capture the full three-dimensional picture of growth plate closure, though it mirrors how such assessments are often done in practice.

Recommendations for Patients and Families

Based on this research, here are practical points to keep in mind:

  1. If your child needs a growth assessment, ask about MRI. MRI can provide detailed information about growth plates without exposing your child to radiation. This is especially relevant for children with conditions that affect growth, such as fractures near the knee, bone infections, or growth disorders.
  2. Ask whether cartilage-specific sequences are included. If the purpose of the MRI is to evaluate growth plate status, cartilage sequences (sometimes called water-selective or water-sensitive sequences) are more reliable than standard T1W sequences alone. You can ask your physician or the imaging center whether these sequences are part of the protocol.
  3. Seek pediatric radiology expertise. The study found that pediatric radiologists were considerably more consistent than general radiologists at grading growth plates — by as much as 34 percentage points for the tibia on T1W sequences. If growth plate assessment is clinically important, it is worth requesting that images be reviewed by a radiologist with pediatric training.
  4. Understand normal variation. Growth plate closure timing varies widely between individuals. Your child may close their growth plates earlier or later than a friend or sibling, and both can be entirely normal. A single age cannot predict exactly when growth will stop for any given individual.
  5. Be cautious about age estimates. If you are in a situation where bone age is being used to estimate chronological age (such as in immigration or sports eligibility contexts), remember that biological age and chronological age are not always the same, and that even reliable MRI readings can only provide an estimate with a range of uncertainty.
  6. Know that a "remnant" finding may be misleading. A residual physis (a visible scar from the former growth plate) can appear on T1W images as if growth is still ongoing, when in fact the growth plate is completely closed. This is normal and common — seen in up to 96–98% of adults in prior studies — and should not be mistaken for continued growth potential.

For clinicians, the study suggests that pediatric radiology experience is preferable when assessing growth plates, that cartilage sequences should be the preferred sequence for this purpose, and that grading scales with fewer sub-stages (without the 4a/4b/4c breakdown) may further improve inter-observer reliability among specialists.

Frequently Asked Questions

What are growth plates and why do they matter?

Growth plates, or physes, are layers of cartilage near the ends of long bones in children and teens where new bone forms as a child grows taller. Problems such as fractures, infections, or bone disorders can disrupt them and cause short stature. Doctors also assess closure for medicolegal reasons, including estimating age when birth records are missing.

How is growth plate closure usually checked, and is there a radiation-free option?

Traditionally, hand and wrist X-rays are used with reference atlases. X-rays expose patients to ionizing radiation and show bone rather than growth plate cartilage directly. MRI is a radiation-free alternative that uses cartilage water content to show the growth plate. In a study of 395 healthy volunteers aged 14 to 21.5, MRI at the knee was used to grade closure.

Which MRI sequence shows growth plate closure more reliably?

In a study of 395 healthy adolescents and young adults, specialized cartilage sequences (water-sensitive types such as 3dWATSc, MERGE, and MEDIC) were consistently more reliable than standard T1-weighted sequences for grading growth plate closure. For pediatric radiologists, agreement on cartilage sequences reached 93 to 95 percent, compared with 82 to 90 percent on T1-weighted images.

Does the radiologist's experience affect how accurately growth plates are read?

Yes. In the same study of 395 healthy volunteers, pediatric radiologists were substantially more consistent than general radiologists. On T1-weighted sequences, pediatric radiologists agreed with each other 82 to 90 percent of the time, while general radiologists agreed only 56 to 69 percent of the time. The difference was largest for the shin bone, where general radiologists' agreement was fair.

What does it mean if an MRI report says stage 4c or stage 5?

The staging system grades how much bone has bridged the growth plate. Stage 4c means more than two-thirds is fused but not complete; stage 5 means complete fusion, with or without a scar. In a study of 395 healthy people aged 14 to 21.5, some older participants were graded stage 4c on T1-weighted images when cartilage sequences showed complete fusion.

Can a visible remnant of the growth plate be mistaken for ongoing growth?

Yes. A residual physis is a remnant that can appear not fully closed on T1-weighted images even when closure is complete. In a study of 395 healthy volunteers, this led some older participants, including a 21-year-old female, to be graded stage 4c instead of stage 5 on T1-weighted images, while cartilage sequences showed no residual cartilage. Prior studies found such scars in up to 96 to 98 percent of adults.

Can MRI of the knee tell exactly when a young person will stop growing?

No. In a study of 395 healthy adolescents and young adults, growth plate closure varied widely between individuals, especially females. Complete closure of the thigh bone was seen as early as age 15 in females on T1-weighted images, yet some females still showed nearly complete closure at age 21. A single age cannot predict when growth will stop for any individual.

If my child's MRI is being used to check whether their knee growth plates have closed, when should I get a second opinion?

Seek a second opinion when growth plate closure matters clinically or legally and the images were read only on standard T1-weighted sequences, or by a radiologist without pediatric training. Cartilage sequences give more reliable agreement than T1W, and pediatric radiologists agree far more often than general radiologists, especially for the tibia. A residual physis on T1W can look like an open growth plate when it is fully fused, so an independent review of the actual images helps confirm the stage. Diagnostic Detectives Network provides independent expert second opinions.

Source Information

Original Article Title: MRI magnetic resonance imaging using cartilage and T1-weighted sequences in the assessment of the closure of the growth plates at the knee

DOI: 10.1177/2058460120962732

Authors: Ola FT Kvist, Ana Luiza Dallora, Ola Nilsson, Peter Anderberg, Johan Sanmartin Berglund, Carl-Erik Flodmark, and Sandra Diaz

Journal: Acta Radiologica Open, Volume 9, Issue 9, pages 1–9 (2020)

DOI: 10.1177/2058460120962732

Author Affiliations: Department of Pediatric Radiology, Karolinska University Hospital, Stockholm, Sweden; Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden; Department of Health, Blekinge Institute of Technology, Karlskrona, Sweden; School of Medical Sciences, Örebro University, Örebro, Sweden; Department of Clinical Sciences in Malmö, Lunds University, Lund, Sweden; and Department of Radiology, Lunds University, Lund, Sweden.

Funding/Access: This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License, which permits non-commercial use, reproduction, and distribution of the work without further permission, provided the original work is attributed as specified on the SAGE and Open Access pages.

This patient-friendly article is based on peer-reviewed research. It is intended for educational purposes only and does not constitute medical advice. Patients with questions about growth plate imaging should consult their healthcare provider. This plain-language summary was prepared to make the study's findings accessible to patients, families, and the general public while preserving all numerical data and scientific conclusions from the original publication.